PT. SABERINDO PACIFIC - FIRE & SAFETY SPECIALIST
Free Member
PT Saberindo Pacific
Contact Information
Name:
Mr. Kusmin T [Marketing]
E-mail:
Homepage:
Instant Messaging:

Y!: kusminardy 
Phone Number:
Phone number of Mr. Kusmin T at Jakarta
Mobile Number:
Mobile number of Mr. Kusmin T at Jakarta
Fax Number:
Fax number of Mr. Kusmin T at Jakarta
Address:
Ruko Mega Grosir Cempaka Mas Blok J no.10 JL. Letjend Suprapto
Jakarta 10640, Jakarta
Indonesia
Average User Review

There is no review for this company

xxxx
Products Gallery
Language :
CHEMGUARD Mobile Foam Cart
CHEMGUARD Mobile....
Harvik - Fireman Boot
Harvik - Fireman....

Products Catalog

Fire Lite' s Conventional Fire Alarm Control Panel / MS-5UD-3[Mar. 22, 2011 9:43:18]
Quantity Order:
Recommend to your friends
Specification
The MS-5UD-3 is a five-zone FACP ( Fire Alarm Control Panel) and the MS-10UD-7( E) is a ten-zone FACP. These control panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional buildings. Both panels include built-in communicators for Central Station Service and remote upload/ download. Each of these FACPs is compatible with System Sensorâ s microprocessor-based i3 series detectors.

These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory â freezeâ signal when the ambient temperature falls below the detector rating. Additionally, both the MS-5UD-3 and MS- 10UD-7 are compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches, and other normally-open contact devices. Refer to the Fire⢠Lite Device Compatibility Document for a complete listing of compatible devices. Outputs include four NACs ( Notification Appliance Circuits) , three programmable Form-C relays ( factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special application resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone line integrity. Activation of a compatible smoke detector or any normallyopen fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the piezo sounder at the FACP, activate the communicator and FACP alarm relay, and operate an optional module used to notify a remote station or initiate an auxiliary control function. New options include a UL listed printer, PRN-6F and FireLiteâ s ACT Internet Monitoring module.

The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line.
You have [3] new inquiries.
Go to Member Menu
Home - Trade List - Product List - Inquiry List - Cooperation List - Company List
Copyright © 2025 Indomonster.com. All Rights Reserved.